Руководство Пользователя для Panasonic th-32lru20

Скачать
Страница из 16
 
 
 
 
 
FMA-101 OVERVIEW 
 
 
PURPOSE AND DEFINITION 
 
The Panasonic Free-To-Guest (FTG) Basic platform delivers FTG channels to the guest rooms 
with minimal headend equipment installed. The FTG Basic platform uses an FTG Management 
Appliance (FMA-101) to configure and deliver the channel lineup to the guest room terminals 
via the hotel’s coaxial distribution network.   
 
 
This document provides the steps to install, configure, and troubleshoot the FMA-101 used in 
the FTG Basic platform. 
 
 
PROCEDURE REQUIREMENTS  
 
Installation and configuration of the FMA-101 requires the following hardware, tools, and 
software. 
 
  FMA-101 
  Minimum termcode requirements: 
o
  HC11 – 2.58 or higher 
o
  HC12 – 6.02 or higher 
  Laptop or tablet with Ethernet port 
  Ethernet crossover cable (for laptop or tablet 
access) 
  Ethernet straight-through cable (for 
hotel network access) 
  Coaxial jumper cables 
  Sencore SLM 1456 meter or 
equivalent  
  Low Pass Filter (6ELP-50 or 6MLP-50)  
 
 
TIPS AND WARNINGS 
 
FMA-101 Configuration 
  The FMA-101 configuration must be performed on site. Remote connectivity for 
configuration or troubleshooting is not available. 
  The FMA-101 should be installed in the FTG rack prior to configuration.  
  If the configuring laptop is running Windows Vista or Windows 7, resetting the power on the 
FMA-101 while the laptop is connected may cause a network conflict issue. To correct a 
network conflict, disable and then enable the network interface on the laptop and refresh 
the browser page. 
  To access the FMA-101 web page, open a browser and type http://fma101 in the address 
bar.  
  The FMA-101 can be configured as a DHCP client or assigned a default IP address.  
o
  DHCP client configuration: