Инструкции По Установке для 3com S7906E

Скачать
Страница из 2621
 
1-8 
          Offline detect period is 180s 
          Quiet period is 180s. 
          Server response timeout value is 100s 
          The max allowed user number is 2048 per slot 
          Current user number amounts to 1 
          Current domain is 2000 
Silent Mac User info: 
         MAC ADDR               From Port           Port Index 
GigabitEthernet2/0/1 is link-up 
  MAC address authentication is enabled 
  Authenticate success: 1, failed: 0 
 Max number of on-line users is 1024 
  Current online user number is 1 
          MAC Addr         Authenticate state           Auth Index 
          00e0-fc12-3456   MAC_AUTHENTICATOR_SUCCESS     29 
<Device> display connection 
Slot:  2 
Index=29  ,Username=aaa@2000 
 IP=N/A 
 MAC=00e0-fc12-3456 
 
 Total 1 connection(s) matched on slot 2. 
 Total 1 connection(s) matched. 
ACL Assignment Configuration Example 
Network requirements 
As shown in 
, a host is connected to port GigabitEthernet 2/0/1 of the switch and must pass 
MAC authentication to access the Internet.  
Specify to use the MAC address of a user as the username and password for MAC authentication 
of the user. 
Configure the RADIUS server to assign ACL 3000.  
On port GigabitEthernet 2/0/1 of the switch, enable MAC authentication and configure ACL 3000. 
After the host passes MAC authentication, the RADIUS server assigns ACL 3000 to port 
GigabitEthernet 2/0/1 of the switch. As a result, the host can access the Internet but cannot access the 
FTP server, whose IP address is 10.0.0.1.