On different devices, the MEPs belonging to the same MD and MA should be configured with the 
same CCM sending interval.  
If the device has multiple cards with assistant CPUs, the CCMs will be sent by one of these cards. 
If the card that sends the CCMs is unplugged, another card will take over to send CCMs and CC 
will be re-performed. If all the cards with assistant CPUs are unplugged, MEPs with the interval 
field value set as 3 will stop sending CCMs immediately, while those with the interval field value set 
as 4 to 7 will send CCMs through their host cards and CC over these MEPs will be re-performed.  
 
The relationship between the interval field value in the CCM messages, the interval between CCM 
messages and the timeout time of the remote MEP is illustrated in 
Table 1-2 Relationship of the interval field value, the interval between CCM messages and the timeout 
time of the remote MEP
The interval field value 
The interval between CCM 
messages 
The timeout time of the 
remote MEP 
100 milliseconds 
350 milliseconds 
1 second 
3.5 seconds 
10 second 
35 seconds 
60 seconds 
210 seconds 
7 600 
seconds 
2100 
seconds 
 
 
In a non-IRF environment with EB or SD cards, the valid value range for the interval field is 3 to 7, while 
in other cases, the valid value range for the interval field is 4 to 7.  
 
Configuring LB on MEPs 
The LB function can verify the link state between two ends after CC detects a link fault. 
Configuration Prerequisites 
Before configuring this function, you should first complete the MEP and MIP configuration tasks.  
Configuration Procedure 
Follow these steps to configure LB on MEP: 
To do... 
Use the command... 
Remarks 
Enter system view 
system-view 
—