1-11 
Configuring the multicast server 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter interface view 
interface interface-type 
interface-number
 
Enter the interface used to 
send NTP multicast message. 
Configure the device to work in 
the NTP multicast server mode 
ntp-service multicast-server 
ip-address ] 
authentication-keyid keyid 
ttl ttl-number | version 
number ] * 
Required 
 
 
A multicast server can synchronize broadcast clients only after its clock has been synchronized. 
You can configure up to 254 multicast clients, among which 128 can take effect at the same time. 
 
Configuring the Local Clock as a Reference Source 
A network device can get its clock synchronized in one of the following two ways: 
Synchronized to the local clock, which works as the reference source. 
Synchronized to another device on the network in any of the four NTP operation modes previously 
described. 
If you configure two synchronization modes, the device will choose the optimal clock as the reference 
source. 
Follow these steps to configure the local clock as a reference source: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Configure the local clock as a 
reference source 
ntp-service refclock-master 
ip-address ] [ stratum ] 
Required