Справочное Руководство для 3com S7906E

Скачать
Страница из 2327
 
3-13 
Parameters 
None
 
Description 
Use the alarm oam error-frame enable command to enable the error frame alarm. 
Use the undo alarm oam error-frame enable command to disable the error frame alarm. 
By default, this function is enabled. 
 
 
The commands here take effect only for OAM 2.0 and above.  
 
Examples 
# Enable the error frame alarm for the ONU corresponding to ONU 3/0/1:1. 
<Sysname> system-view 
[Sysname] interface onu 3/0/1:1 
[Sysname-Onu3/0/1:1] alarm oam error-frame enable 
alarm oam error-frame-seconds-summary 
Syntax 
alarm oam error-frame-seconds-summary { window window | threshold threshold } 
undo alarm oam error-frame-seconds-summary { window | threshold } 
View 
OLT port view, ONU port view, FTTH view 
Default Level 
2: System level 
Parameters 
window  window: Specifies the window size, in the range 100 to 9000 (in 100 ms). By default, the 
window size is 600. 
threshold threshold: Specifies the alarm threshold, in the range 1 to 900 (in seconds). By default, the 
threshold is 1 second. 
Description 
Use the alarm oam error-frame-seconds-summary command to configure the corresponding 
window size and alarm threshold. 
Use the undo  alarm oam error-frame-seconds-summary to restore the default window size and 
alarm threshold.