Use No. 10AWG (5.3 mm
2
) copper, No. 
8AWG (8.4 mm
2
) aluminum, No. 17AWG 
(1.0 mm
2
) copper-clad steel or bronze 
wire, or larger, as a ground wire.
Secure antenna lead-in and ground wires 
to house with stand-off insulators spaced 
from 4-6 feet (1.22-1.83 m) apart.
Mount antenna discharge unit as close as 
possible to where lead-in enters house.
Use jumper wire not smaller than No. 
6AWG (13.3 mm
2
) copper, or the 
equivalent, when a separate 
antenna-grounding electrode is used. See 
ANSI/NFPA70.
An outside antenna system should not be 
located in the vicinity of overhead power 
circuits, or where it can fall into such power 
lines or circuits. When installing an outside 
antenna system, extreme care should be 
taken to keep from touching such power lines 
or circuits as contact with them might be fatal.
For added protection for this television during 
a lightning storm, or when it is left unattended 
and unused for long periods of time, unplug it 
from the power outlet and disconnect it from 
the antenna or cable system. This prevents 
damage to the television due to lightning and 
power line surges.
Do not overload power outlets and extension 
cords, because overloading can cause a fire 
or electric shock.
Never push objects of any kind into this 
television through slots in the case, because 
they may touch dangerous voltage points or 
short out parts that could result in a fire or 
electric shock. Never spill liquid of any kind 
on the television.
Do not attempt to service this television 
yourself, because opening or removing 
covers may expose you to dangerous 
voltages or other hazards. Refer all servicing 
to qualified service technicians.
Unplug this television from the power outlet 
and refer servicing to qualified service 
technicians under the following conditions:
When the power cord or plug is damaged 
or frayed.
If liquid has been spilled into the 
television.
If the television has been exposed to rain 
or water.
If the television does not operate normally 
by following the operating instructions. 
Adjust only those controls that are 
covered by the operating instructions, 
because incorrect adjustment of other 
controls may result in damage and often 
requires extensive work by a qualified 
technician to restore normal operation.
If the television has been dropped or the 
case has been damaged.
When the television exhibits a distinct 
change in performance.
When replacement parts are required, be 
sure the service technician has used 
replacement parts specified by the 
manufacturer that have the same 
characteristics as the original part. 
Unauthorized substitutions may result in fire, 
electric shock, or other hazards.
Upon completion of any service or repairs to 
this television, ask the service technician to 
perform routine safety checks to determine 
that the television is safe to operate.
Note to cable television system installer
This reminder is provided to call the cable 
television system installer’s attention to Section 
820 40 of the NEC which provides guidelines for 
proper grounding and, in particular, specifies 
that the cable ground shall be connected to the 
grounding system of the building, as close to the 
point of cable entry as practical.
Reference
Grounding component
1
Electric service equipment
2
Power service grounding 
electrode system
(NEC Art 250, Part H)
3
Ground clamp
4
Grounding conductors (NEC 
Section 810-21)
5
Antenna discharge unit (NEC 
Section 810-20)
6
Ground clamp
7
Antenna lead-in wire
6
7
5
2
1
3
4