7
Lamp in projector:
SP2xxx — 2000 lumen, uses a 360 watt EYB lamp, Dukane Part
Number 456-186.
SP4xxx — 4000 lumen, uses a 410 watt FXL lamp, Dukane Part
Number 456-192.
SP3xxx — 3000 lumen, uses a 360 watt ENX lamp, Dukane Part
Number 458-188.
LAMP REPLACEMENT
WARNING
Lamp and adjacent metal parts are hot. Allow lamp to cool
before replacing. Glass components may shatter.
Handle carefully.
Lamp replacement, SP2xxx units:
1. Open unit stage by depressing the latch tabs on front of stage
and lifting (Step 1). Remove the stage.
2. Carefully pull out used lamp. Take caution since it may be hot.
Allow time to cool (Step 2).
3. Push new lamp in socket until firmly seated. Avoid skin oil on
bulb. Hold lamp with a cloth, tissue or gloved hand.
4. Replace stage by aligning rear edge and then pushing down the
front until it locks into place.
FOR 2000 LUMEN MODELS —
Open stage.
S
TEP
 1 —