RS-232 commands
IMPORTANT:
When formatting commands sent from a control system or
computer, enclose commands in parentheses “(“ and “)”. When entering
custom commands into Scheduled Tasks in the projector’s web interface,
enclose commands in less than/greater than symbols “<” and “>” instead.
Communication Configuration
Visit our website for additional RS-232 settings and information.
Visit our website for additional RS-232 settings and information.
To control this projector via RS-232, connect a null modem cable and set the
control system serial port settings to match the following communication
configuration:
Command Format
All commands consist of 3 alpha characters followed by a request, all
All commands consist of 3 alpha characters followed by a request, all
enclosed in parentheses. The request can be a read request (indicated by
a"?") or a write request (indicated by 1 to 4 ASCII digits).
A read request example:
(AAA?) where
(starts the command
AAA denotes the command
? denotes the read request
) ends the command
A read command returns the range and the current setting, for example:
A write request example:
(AAA####) where
(starts the command
AAA denotes the command
#### denotes the value to be written
(leading zeros not necessary)
) ends the command
Some commands have ranges, while others are absolute. If a number
greater than the maximum range is received, it is automatically set to the
maximum number for that function. If a command is received that is not
understood, a "?" is returned. With absolute settings, "0" is off, 1-9999 is on.
The one exception is the Power command, where 0 is off and 1 is on.
To assure the projector can process a command, wait 3 seconds before
entering the next command.
RS-232 Port Settings
Setting
Value
Bits per second
115,200
Data bits
8
Parity
None
Stop bits
1
Flow control
None
Emulation
VT100
Read Command Examples
Function
Commend
Response
Brightness
(BRT?)
(96-160,128)
Volume
(VOL?)
(0-32, 0)
Lamp Hours
(LMP?)
(0-32766, 42)