Calibrating the Touch Screen
If the touch points on the library’s touch screen do not properly align with 
the user interface graphics, perform the following procedure to recalibrate 
the position of the touch points.
Note:
This procedure is not necessary or helpful unless recommended 
by SpectraGuard Technical Support.
Note:
You must perform this procedure while standing in front of the 
touch screen.
1. From the toolbar menu, select Maintenance > Tools. The Maintenance 
Tools screen displays.
2. Select Utilities. The Utilities screen displays.
3. Select Calibrate Touch Screen. The touch screen displays a series of 
calibration target points. Touch each point as it displays with either 
your finger or a stylus to recalibrate the touch points on the screen.
Note:
Touch each point at a straight-on angle as close to the center of 
the target as possible.
4. When the calibration routine is complete, the Utilities screen redisplays.
Restoring the Library Configuration
If you have valid backups of the library’s configuration and MLM 
database, you can use them to restore the library in the event of a disaster. 
You can also uses these backups to restore the library if problems require 
you to replace the LCM or the LCM’s compact flash card.
ƒ
ƒ
ƒ
Restoring From an Auto-Save Configuration File
The advanced utility called Restore Library Configuration From Auto Save 
lets you restore the library configuration and MLM database using the 
auto-save backup file (see 
).
Caution
Before restoring your system using the auto-save file, check the time stamp 
included in the file name to ensure that you have the most current file.
Important
The library does not automatically save a backup when you make changes to any 
of the library configuration settings other than those for partitions. Changes will be 
saved during the next weekly automatic configuration save operation.