Release Note для Spectra Logic spectra t120

Скачать
Страница из 222
Restoring the Library Configuration
December 2008
Spectra T950 Library
165
ƒ Restore Library To Backup Configuration. Use this option to restore 
the previous configuration after mistakenly running the Reset to 
Factory Defaults
 utility. 
The screen refreshes to show the details for the selected restore utility.
6. Select Run Utility.
After a brief delay, the Utility Results screen appears, showing that the 
configuration file was uploaded and/or the configuration restored.
Restoring the MLM Database
Use the following steps to restore the MLM database from a previously 
saved backup that was created using the Save MLM Database utility (see 
1. If you plan to restore using the MLM database backup file that was sent 
as an email attachment, use the following instructions to copy the file to 
a USB key; otherwise, skip to 
.
a. Create a folder called SavedMLMDB on a USB key.
b. Copy the 
cminfo_<date-time>.dat
 file to the SavedMLMDB folder 
on the USB key.
2. If you plan to restore a using an MLM database file stored on a USB key, 
plug the USB key into the USB port on the LCM before continuing.
3. Log into the library with superuser or administrator privileges.
4. Select Maintenance > Tools > Utilities. The Utilities screen displays.
5. Select Show Advanced. The Advanced Utilities Confirmation screen 
displays.
6. Select Next. The Utilities screen refreshes to show the advanced Utilities 
screen.