The maximum load of each voltage output can not excess the definition as above table.
4.3. HOLD-UP TIME (@FULL LOAD)
115V / 60Hz : 5 mSec. Minimum.
230V / 50Hz : 5 mSec. Minimum.
The output voltage will remain within specification, in the event that the input power is removed or
interrupted, for the duration of one cycle of the input frequency. The interruption may occur at any
point in the AC voltage cycle. The power good signal shall remain high during this test.
4.4.OUTPUT RISE TIME
< 20mS at the condition of 10% TO 90% OF NOMINAL OUTPUT VALUE @ FULL LOAD
4.5.OVER VOLTAGE PROTECTION
The power supply unit shall shutdown and auto-recovery when the abnormal1 condition
removed before the output voltage reaching 30V.
4.6.OVER CURRENT PROTECTION
The output will shutdown and auto-recovery before the output current reaching 7A.
4.7.SHORT CIRCUIT PROTECTION
Output short circuit is defined to be a short circuit load of less than 0.1 ohm.
5.0 ENVIRONMENTAL REQUIREMENTS
The power supply will be compliant with each item in this specification for the following
Environmental conditions.
5.1. TEMPERATURE RANGE
Operating
0 to +35 deg. C
Storage
-20 to +70 deg. C
5.2. HUMIDITY