DAS3series LCT Operation Menus 
75 
SELT Test 
 
SELT (Single End Loop Test) is single-ended test, meaning that a copper loop is tested from the 
DSLAM only, without the need for any external test equipment in either the CO or at the remote end 
of the loop. SELT is primarily used for PROACTIVE loop pre-qualification. By knowing in advance if 
a loop is capable of supporting ADSL2+. By determining distance, wire gauge and noise, loop 
conditions can be fixed prior to rolling a truck to the customer premise. This not only saves time and 
money, but also improves customer satisfaction by avoiding “false start” installations. 
 
Figure 3-62 
SELT Test Dialog 
 
 
Table 3-46 
SELT Testing Dialog 
Item 
Description 
Port selection menu 
Please select port from pull down menu 
Value   
Display various field obtains during SELT test.   
 
 
DAS3series IP-DSLAM 
System Configuration Guide