Справочное Руководство для D-Link DFL-1600
![D-Link](https://files.manualsbrain.com/attachments/a3b69a1096815cc2a385543f7ff1659518d26077/common/fit/150/50/4d67db14f9c80bd5038e27f2797c96588bc08259be139ec4247ec53f0ef2/brand_logo.jpeg)
2.45. TIMESYNC
These log messages refer to the TIMESYNC (Firewall time synchronization events) category.
2.45.1. synced_clock (ID: 03500001)
Default Severity
Log Message
The clock at <oldtime>, was off by <clockdrift> second(s) and
synchronized with <timeserver> to <newtime>
synchronized with <timeserver> to <newtime>
Explanation
The clock has been synchronized with the time server.
Gateway Action
None
Recommended Action
None.
Revision
2
Parameters
oldtime
newtime
clockdrift
timeserver
newtime
clockdrift
timeserver
2.45.2. failure_communicate_with_timeservers (ID:
03500002)
03500002)
Default Severity
Log Message
Communication with the timeserver(s) failed. Clock not updated.
Explanation
The unit failed to establish a connection with the time sync server. The
clock has not been updated.
clock has not been updated.
Gateway Action
clock_not_synced
Recommended Action
Verify that the time sync server is running.
Revision
1
2.45.3. clockdrift_too_high (ID: 03500003)
Default Severity
Log Message
According to the timeserver the clock has drifted <clockdrift>
seconds(s) which is NOT in the allowed correction interval
(+/-<interval> seconds)
seconds(s) which is NOT in the allowed correction interval
(+/-<interval> seconds)
Explanation
The clock has drifted so much that it is not within the allowed +/-
correction interval. The clock will not be updated.
correction interval. The clock will not be updated.
Gateway Action
clock_not_synced
Recommended Action
If the correction interval is too narrow, it can be changed in the
Advanced Settings section.
Advanced Settings section.
2.45. TIMESYNC
Chapter 2. Log Message Reference
443