Использование И Уход для KitchenAid 36" Wall-Mount, 3-Speed Canopy Hood

Скачать
Страница из 32
10
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install 
a UL listed or CSA approved
 ¹⁄₂" strain relief.
4. Run home power supply cable through strain relief 
into terminal box.
5. Use UL listed wire connectors and connect black 
wires (C) together.
6. Use UL listed wire connectors and connect white 
wires (E) together.
7. Connect green (or bare) ground wire from home power supply 
to yellow-green ground wire (F) in terminal box using UL listed 
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions 
supplied with the power cord kit. See the “Assistance or Service” 
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have 
been investigated and found acceptable for use with this model 
range hood.
A. Knockout
B. Terminal box cover
C. Screws (7)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
C
C
C
A. Home power supply cable
B. UL listed or CSA approved 
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
A
B
C
D
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.