Руководство По Установке для KitchenAid 30-Inch 4-Element Electric Downdraft Slide-In Range

Скачать
Страница из 52
7
Venting Requirements
IMPORTANT: This range must be exhausted outdoors unless 
you are using ductless venting. See the “Venting Methods” 
section.
 
Do not terminate the vent system in an attic or other 
enclosed area.
 
Use an approved vent cap for proper performance. If an 
alternate wall or roof cap is used, be certain the cap size  
is not reduced and that it has a backdraft damper.
 
Vent system must terminate to the outside unless you are 
using a ductless vent kit.
 
Use a 5" (12.7 cm) or 6" (15.2 cm) round metal vent  
or a 3¼" x 10" (8.3 cm x 25.4 cm) rectangular vent.
 
Rigid metal vent is recommended. For best performance, 
do not use plastic or metal foil vent.
 
If a joist or stud must be cut, then a supporting frame must 
be constructed.
 
The size of the vent should be uniform.
 
The vent system must have a damper.
 
Seal all joints in the vent system.
 
Use caulking to seal exterior wall or roof opening around 
the cap.
 
Determine which venting method is best for your 
application.
For Best Performance:
 
Use 26-gauge minimum galvanized or 25-gauge minimum 
aluminum metal vent. Poor quality pipe fittings can reduce 
airflow. For external venting, flexible metal vent is not 
recommended.
 
NOTES:
   For external venting, flexible metal vent is not 
recommended. Flexible vent creates back pressure  
and air turbulence that greatly reduce performance.
  Local codes may require a heavier gauge material.
 
Metal duct may be reduced to 30-gauge galvanized steel 
or 26-gauge aluminized steel if allowed by local codes. 
This reduction is based on information in the International 
Residential Codes Section M1601.1 (2006 edition).
 
Avoid installing 2 elbows together.
 
Use no more than three 90° elbows.
 
Make sure there is a minimum of 18" (45.7 cm) of straight 
vent between the elbows if more than one elbow is used. 
Elbows too close together can cause excess turbulence 
that reduces airflow.
 
Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm)  
or 3¼" x 10" (8.3 x 25.4 cm) system.
 
Do not reduce to a 5" (12.7 cm) system after using  
a 6" (15.2 cm) or 3¼" x 10" (8.3 x 25.4 cm) fittings.
 
Avoid forming handmade crimps. Handmade crimps  
may restrict airflow.
The length of vent system and number of elbows should be 
kept to a minimum to provide efficient performance.
The maximum equivalent length of the vent system is 60 ft  
(18.3 m). For altitudes above 4,500 ft (1272 m), reduce 
recommended vent run by 20% for best performance.
Cold Weather Installations
An additional backdraft damper should be installed to  
minimize backward cold air flow and a thermal break installed 
to minimize conduction of outside temperatures as part  
of the vent system. The damper should be on the cold  
air side of the thermal break.
Order Part Number 708786A for a 5" (12.7 cm) thermal break.
Order Part Number 715557A for a 6" (15.2 cm) thermal break.
To order, see the “Assistance or Service” section of the Use  
and Care Guide.
Makeup Air
Local building codes may require the use of makeup air 
systems when using ventilation systems greater than specified 
CFM of air movement. The specified CFM varies from locale  
to locale.
Consult your HVAC professional for specific requirements  
in your area.
Venting Methods
Common venting methods are shown for a downdraft range.  
The downdraft range may be vented through the wall or floor.
Wall Venting
Floor Venting
Venting Between Floor Joists
A. Wall cap
B. Venting
A. Wall cap
B. Venting
A
B
A. Wall cap
B. Venting
A
B
A. Wall cap
B. Venting