Electrical Requirements – U.S.A. Only
Be sure that the electrical connection and wire size are 
adequate and in conformance with the National Electrical 
Code, ANSI/ NFPA 70-latest edition and all local codes and 
ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding  
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as 
to whether the appliance is properly grounded. Do not modify 
the power supply cord plug. If it will not fit the outlet, have a 
proper outlet installed  by a qualified electrician.
Electrical Connection
Check local codes and consult gas supplier. Check 
existing electrical supply and gas supply. See “Gas Supply 
Requirements” section.
It is recommended that all electrical connections be made by  
a licensed, qualified electrical installer.
 
Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial/rating plate. 
The model/serial/rating plate is located on the right vertical 
surface of the oven door frame. Refer to the illustrations 
in the “Product Dimensions” section of the “Location 
Requirements” section.
 
This range is manufactured with a 4-wire power supply 
cord rated at 240 volts, 40 amps, rated at 194°F (90°C)  
and investigated for use with this range.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
Temp Rating
8.8–16.5 kW
7.8–12.5 kW
40 or 50
194°F (90°C)
16.6–22.5 kW
12.6–18.5 kW
50
194°F (90°C)
* The NEC calculated load is less than the total connected load listed  
on the model/serial/rating plate.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or 
electrical shock.
 
When a 4-wire, single phase 240 volt, 60 Hz., AC only 
electrical supply is available, a 40-amp minimum circuit 
protection is required on 30" (76.2 cm) ranges, fused  
on both sides of the line.
 
A time-delay fuse or circuit breaker is recommended.
 
This range is equipped with a UL or CSA International 
Certified Power Cord intended to be plugged into  
a standard 14-50R wall receptacle. Be sure the wall 
receptacle is within reach of range’s final location.
 
Do not use an extension cord.
 
The wiring diagram is located on the back of the range  
or in a clear plastic bag.