Справочник Пользователя для ASUS P9D-C/4L

Скачать
Страница из 42
33
10. 
Enabling the Disk Write Cache (DWC)
You may manually enable the RAID controller’s Disk Write Cache option after creating a 
RAID set to improve the data transmission performance. 
3. 
Select On from the Change DWC and press <Enter> to turn on the option. 
4. 
Go to Management Menu, select Objects > Virtual Drive. Select an existing Virtual 
Drive and press <Enter>. 
When you enable DWC, you may lose data when a power interruption occurs while transmitting 
or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets. You have to 
manually configure the Adapter and the Virtual Drive of the RAID set you created.
To enable DWC:
1. 
From the Management Menu, select Objects > Adapter. Select an existing adapter 
then press <Enter> to display the adapter properties.
2. 
Select Disk WC then press <Enter>.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Oct 26, 2011
BIOS Version  A.11.02090932R
Disk Write Cache - Off(Write Through or On(Write Back)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
Rebuild Rate   = 30
Chk Const Rate = 30
FGI Rate       = 30
BGI Rate       = 30
Disk WC        = Off
Read Ahead     = On
Bios State     = Enable
Cont On Error  = Yes
Fast Init      = Enable
Auto Rebuild   = On
Auto Resume    = Enable
Disk Coercion  = 1GB
Factory Default
Adapter 0