Справочник Пользователя для ASUS RS724Q-E7/RS12

Скачать
Страница из 202
6-18
Chapter 6: RAID configuration
6.2.5 
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual drive. 
The utility can automatically detect and/or detect and correct any differences in data 
redundancy depending on the selected option in the Objects > Adapter menu.
The Check Consistency command is available only for virtual drives included in 
a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
1.  From the Management Menu, select Check Consistency, and then press 
<Enter>.
2.  The screen displays the available RAID set(s) and prompts you to select the 
virtual drive to check. Press <Space> to select the virtual drive from the Virtual 
Drive sub-menu, and then press <F10>.
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
CC Of VD(s)
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version   A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
Select VD
Virtual Drive(s) Configured
LD    RAID    Size    #Stripes    StripSz   Status
0      1    148.580GB     2        64 KB     ONLINE
Virtual Drives
Virtual Drive 0
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version   A.10.09231523R
SPACE-(De)Select,   F10-Check Consistency