Справочник Пользователя для ASUS RS700-E7/RS8

Скачать
Страница из 194
6-18
Chapter 6: RAID configuration
6.2.5 
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual 
drive. The utility can automatically detect and/or detect and correct any differences 
in data redundancy depending on the selected option in the Objects > Adapter 
menu.
The Check Consistency command is available only for virtual drives included 
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
1.  From the Management Menu, select Check Consistency, and then press 
<Enter>.
2.  The screen displays the available RAID set(s) and prompts you to select 
the virtual drive to check. Press <Space> to select the virtual drive from the 
Virtual Drive sub-menu, and then press <F10>.
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
CC Of VD(s)
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version   A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
Select VD
Virtual Drive(s) Configured
LD    RAID    Size    #Stripes    StripSz   Status
0      1    148.580GB     2        64 KB     ONLINE
Virtual Drives
Virtual Drive 0
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
BIOS Version   A.10.09231523R
SPACE-(De)Select,   F10-Check Consistency