Руководство Пользователя для ASUS TS300-E9-PS4

Скачать
Страница из 166
6-10
Chapter 6: RAID Configuration
3. 
The utility immediately starts rebuilding after the disk is selected. When done, the 
status of the degraded RAID volume is changed to “Rebuild”.
4. 
Press <Esc> to exit Intel Rapid Storage Technology and reboot the system. 
5. 
Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or 
click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage 
Manager utility.
6. 
From the View menu, select Advanced Mode to display the details of the Intel Rapid 
Storage Console.
7. 
From the Volumes view option, select RAID volume to view the rebuilding status. 
When finished, the status is changed to “Normal”.
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system displays the 
status of the RAID volume as “Degraded” during POST. You may replace the disk drive and 
rebuild the RAID array.
To rebuild the RAID with a new hard disk:
1. 
Remove the failed SATA hard disk and install a new SATA hard disk of the same 
specification into the same SATA Port.
[ESC]-Exit
[ENTER]-Select Menu
[  ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation.  All Rights Reserved.
[
 MAIN MENU 
]
[
 DISK/VOLUME INFORMATION
]
RAID Volumes:                                      *=Data is Encrypted
ID   Name      Level1          Strip         Size   Status    Bootable
1    Volume0   RAID1(Mirror)   N/A        149.0GB   
Rebuild
   Yes
Physical Devices:   
Port  Drive Model   Serial #              Size    Type/Status(Vol ID)
1     ST3160812AS   9LS0F4HL           149.0GB    
Member Disk(0)
2     ST3160812AS   3LS0JYL8           149.0GB    
Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
Select a destination disk with the same size as the original hard disk.
2. 
Reboot the system then follow the steps in section Rebuilding the RAID with other 
non-RAID disk