Справочник Пользователя для ASUS ESC8000 G3

Скачать
Страница из 206
6-10
Chapter 6: RAID configuration
Using New Configuration
When a RAID set already exists, using the New Configuration command erases the existing
RAID configuration data. If you do not want to delete the existing RAID set, use the View/
Add Configuration command to view or create another RAID configuration.
To create a RAID set using the New Configuration option
1.
From the Management Menu, select Configure > New Configuration, and then press
<Enter>.
2.
Follow step 2 to 9 of the previous section: Using Easy Configuration.
3.
Select Size from the Virtual Drive menu, and then press <Enter>.
4.
Key-in the desired virtual drive size, and then press <Enter>.
5.
Follow step 10 to 14 of the previous section: Using Easy Configuration to create the
RAID set.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version  A.10.09231523R
Clear Existing Configuration And Start A New Configuration
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version  A.10.09231523R
Enter VD Size:
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD      RAID    Size       #Stripes     StripSz     Status
0         1     148.580GB      2         64KB       ONLINE
RAID = 1
Units= MB
Size = 152146MB
DWC  = OFF
RA   = On
Accept
SPAN = NO
Virtual Drive 0
Enter VD Size: 152146_