Руководство Пользователя для ASUS RS720Q-E8-RS12
5-15
RS720Q-E8-RS12
Terminal Type [VT-UTF8]
Allows you to set the terminal type.
[VT100]
Allows you to set the terminal type.
[VT100]
ASCII char set.
[VT100+]
Extends VT100 to support color, function keys, et.
[VT-UTF8]
Uses UTF8 encoding to map Unicode chars onto 1 or more bytes
[ANSI]
Extended ASCII char set
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Configuration options: [9600] [19200] [38400] [57600] [115200]
Data Bits [8]
Configuration options: [7] [8]
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
Configuration options: [7] [8]
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
and [Space] parity do not allow for error detection.
[None]
[None]
None
[Even]
parity bit is 0 if the num of 1’s in the data bits is even
[Odd]
parity bit is 0 if num of 1’s in the data bits is odd
[Mark]
parity bit is always 1
[Space]
parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit. Configuration options: [1] [2]
Flow Control [Hardware RTS/CTS]
Flow control can prevent data loss from buffer overflow. When sending data, if the
Flow Control [Hardware RTS/CTS]
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a “stop” signal can be sent to stop the data flow. Once the
buffers are empty, a “start” signal can be sent to re-start the flow. Hardware flow control
uses two wires to send start/stop signals.
Configuration options: [None] [Hardware RTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
terminals. Configuration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
With this mode enabled only text will be sent. This is to capture Terminal data.
Recorder Mode [Disabled]
With this mode enabled only text will be sent. This is to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
This allows you to set the number of rows and columns supported on the Legacy OS.
Configuration options: [80x24] [80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty. Configuration options:
This allows you to select the FunctionKey and Keypad on Putty. Configuration options:
[VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]