Инструкция для Canon imagePROGRAF iPF6400S

Скачать
Страница из 164
iPF6400S Basic Guide 
 150 
Er
ror M
essa
ge
Me
ssa
ges
 r
egar
ding 
pr
inti
ng 
or
 a
djus
tm
ent 
Please commn calibrt using above paper. 
Cause 
Corrective Action 
It is now recommended that you 
execute Common calibration. 
Note that this is displayed when 
Set Exec. Guide in the Control 
Panel menu is set to On and any 
of the following is true. 
•  If the printer is loaded with a 
type of paper on which color 
calibration cannot be executed 
and the predefined conditions 
since executing the Common 
calibration the last time have 
been reached. 
•  Although a media type that 
color calibration can be 
executed on is loaded in the 
printer, there is no record or 
performing color calibration on 
that media, and the designated 
criteria from executing 
Common calibration the last 
time have been reached. 
Execute Common calibration. 
(See "Color Calibration Using the Printer Sensor.")➔User's Guide 
Set Set Exec. Guide to Off on the Control Panel menu. 
(See "Menu Structure.")➔P.66 
 
Please calibrate using above paper. 
Cause 
Corrective Action 
It is now recommended that you execute Unique calibration. 
Note that this is displayed when Set Exec. Guide in the Control Panel menu is 
set to On and any of the following is true. 
•  If the printer is loaded with a type of paper on which color calibration can be 
executed, but there is no record of having executed color calibration on 
that paper or a record of having executed Common calibration other any 
other type of paper. 
•  If the printer is loaded with a type of paper on which color calibration can be 
executed, there is a record of having executed color calibration on that 
paper, and the predefined conditions since executing the color calibration 
the last time have been reached. 
•  The Spectrophotometer Unit (optional) is installed. Although a media type 
that color calibration can be executed on using the Spectrophotometer Unit 
is loaded in the printer and the result of a color check on that media 
exceeded the threshold value, the color calibration has not been 
performed. 
(See "Color Checks Using the Spectrophotometer Unit (option).")➔User's 
Guide
 
Execute Unique calibration. 
(See "Color Calibration Using the Printer 
Sensor.")➔User's Guide 
(See "Color Calibration Using the 
Spectrophotometer Unit (option).")➔
User's Guide 
Set Set Exec. Guide to Off on the 
Control Panel menu. 
(See "Menu Structure.")➔P.66 
 
Before borderless printing, move the blue platen switch. 
Cause 
Corrective Action 
The blue Switch on the platen was set to the side opposite 
●  when a borderless print job was received. 
Before borderless printing, set the blue Switch on the platen 
to the 
● side. 
(See "Setting the Blue Switch on the Platen.")➔P.120