Техническое Руководство для Canon CI-1000GA
Interpolator Board CI-200GA, CI-1000GA
Input signals
Canon encoder A-phase, B-phase sine wave signal and Z-
phase signal
Number of divisions
1000, 800, 500, 400, 250, 200, 125, 100 - fold (CI-1000GA)
200, 160, 100, 80, 50, 40, 25, 20 - fold (CI-200GA)
Maximum frequency response
~ 100 kHz (CI-1000GA)
~ 343 kHz (CI-200GA)
(Note) The response frequency varies depending on the
number of divisions
Output signals
up / down pulse
signal
Line driver output (CI-1000GA only)
A, B phase signal
Divided rectangle signal ( PCA+, PCB+, PCA-, PCB- ),
Differential line driver
Z phase signal
Square wave signal ( PCZ+, PCZ- ), Differential line driver
Alarm
output when the encoder signal fails and when the
maximum response frequency is exceeded.
LD Alarm
Open corrector (notice of time for LD exchange)
Filter function
1. Gridge filter
2. Output pulse interval time-setting function
Power
DC - 5.00 V ± 5 % 50 mA max,DC + 5.00 V ± 5 % 200 mA
max
External Dimensions
140 x 65 mm
Attachment
Power cable, rotary encoder connection cable, D-sub
mini15 pin connector
Ambient
conditions
Operating
Temperature
0 to 50 ºC
Storage
Temperature
- 20 to 70 ºC
Operating
Humidity
90 % RH or less (no condensation)
Interpolator Board CI-1000GA
Product Specifications
© 2015 Canon U.S.A., Inc. All Rights Reserved. Reproduction in whole or part without permission is prohibited.
Main Unit Spec