Installation Dimensions
IMPORTANT:
Minimum distance “X”: 24" (61 cm) from electric 
cooking surfaces
Minimum distance “X”: 30" (76.2 cm) from gas 
cooking surfaces
The chimneys can be adjusted for different ceiling heights. 
See the following chart.
Vented Installations
Min. ceiling height
Max. ceiling height
Electric cooking 
surface
7' 9" (2.36 m)
10' 2" (3.1 m)
Gas cooking 
surface
8' 3" (2.51 m)
10' 2" (3.1 m)
*
NOTE: The range hood chimneys are adjustable and designed 
to meet varying ceiling or soffit heights depending on the 
distance “X” between the bottom of the range hood and 
the cooking surface. For higher ceilings, an Extension Kit 
Part Number W10352733 is available from your dealer or an 
authorized parts distributor. The chimney extension replaces 
the chimney shipped with the range hood.
Venting Requirements
 
Vent system must terminate to the outdoors.
 
Do not terminate the vent system in an attic or other 
enclosed area.
 
Do not use 4" (10.2 cm) laundry-type wall caps.
 
Use metal vent only. Rigid metal vent is recommended. 
Plastic or metal foil vent is not recommended.
 
The length of vent system and number of elbows should 
be kept to a minimum to provide efficient performance.
For the Most Efficient and Quiet Operation:
 
Use no more than three 90° elbows.
 
Make sure there is a minimum of 24" (61.0 cm) of straight 
vent between the elbows if more than 1 elbow is used.
 
Do not install 2 elbows together.
 
Use clamps to seal all joints in the vent system.
 
The vent system must have a damper. If the roof or wall 
cap has a damper, do not use the damper supplied with 
the range hood.
 
Use caulking to seal exterior wall or roof opening 
around the cap.
 
The size of the vent should be uniform.
Cold Weather Installations:
An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed 
to minimize conduction of outside temperatures as part of the 
vent system. The damper should be on the cold air side of the 
thermal break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
Makeup Air:
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of 
air movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in 
your area.
Venting Methods
Typical Internal Blower Motor System 
Venting Installations:
A 10" (25.4 cm) round vent system is needed for 
installation (not included). The range hood exhaust 
opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent 
creates back pressure and air turbulence that greatly 
reduce performance.
Vent system can terminate either through the roof or wall. 
To vent through the wall, a 90º elbow is needed.
18" (45.7 cm) min. 
clearance upper 
cabinet to countertop
X*
36" (91.4 cm) 
countertop height
See Note*
36" (91.4 cm) or 48" (121.9 cm) 
or cabinet opening width
(if installed between cabinets)