INSTALLATION
This  canopy  hood  is  designed  to  be  fixed  to  any  rigid  vertical  surface,  over  a  gas  or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling).
Safety  warnings
• Before  commencing  the  installation,  consideration  should  be  given  to  the  difficulties
to  be  found  during  installation  and  to  the  bulky  weight  of  the  hood.  The  installation
work  must  be  undertaken  by  a  qualified  and  competent  person  in  conformity  to  the
rules  concerning  the  evacuation  of  contaminated  air.  The  manufacturer  disclaims  all
liability  for  any  damage  or  injury  caused  as  a  result  of  not  following  the  instructions
for  installation  contained  in  the  following  text.
• When used in the extraction mode the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than  electric  such  as  a  central  heating  flue  or  water  heating  flue.
• When installed, the hood must be positioned at least 65 cm above a cooking appliance.
• Never  do  flambé  cooking  under  this  cooker  hood.
• Never leave frying pans unattended during use as overheated fats and oils may catch
fire.
• If  the  room  where  the  cooker  hood  is  to  be  used  contains  a  fuel  burning  appliance
such as a central heating boiler then this must be of the room sealed or balanced flue
type.  If  other  types  of  flue  or  appliance  are  fitted  ensure  that  there  is  an  adequate
supply  of  air  into  the  room.  When  the  cooker  hood  is  used  in  conjunction  with  other
appliances supplied with energy other than electric, the negative pressure in the room
must  not  exceed  0,04  mbar  to  prevent  fumes  being  drawn  back  into  the  room  by  the
cooker  hood.
Components
The cooker hood is made up of the following components (fig 1):
• n. 1 hood canopy C complete with controls, lighting and fan motor.
• n. 1 telescopic chimney stack formed by:
n. 1 U-shaped upper section item S
n. 1 U-shaped lower section item I
• n. 2 recirculation venting grilles item (special versions only)
• n. 1 reduction flange Ø 150-120 A
• n. 1 recirculation spigot item R
• n. 1 deflector D (special versions only)
• n. 1 additional recirculation spigot P (special versions only)
• n. 1 plastic bag containing:
n. 2 wall brackets 1 to fix the canopy hood
n. 2 wall brackets to fix the chimney, rawl plugs, screws, and documentation
• n. 1 splashback B (optional)