Installing Electrical Interface Assemblies in the 
Cisco ONS 15454
Product Numbers: 15454-EIA-BNC-A24=, 15454-EIA-BNC-B24=, 15454-EIA-BNC-A48=, 
15454-EIA-BNC-B48=, 15454-EIA-SMB-A84=, 15454-EIA-SMB-B84=, 15454-EIA-AMP-A84=, 
15454-EIA-AMP-B84=, 15454-EIA-1BNCA24=, 15454-EIA-1BNCB24=, 15454-EIA-1BNCA48=, 
15454-EIA-1BNCB48=, 15454-EIA-1SMBA84=, 15454-EIA-1SMBB84=, 15454-EIA-1AMPA84=, 
15454-EIA-1AMPB84=
This document describes how to install Electrical Interface Assemblies (EIAs) for the Cisco ONS 15454. 
EIAs are pre-installed on the ONS 15454 when ordered with the system. EIAs host a special card that 
provides coaxial cable connection points (SMB or BNC) for the DS-3 or EC-1 cards. EIAs also host twisted 
pair wire-wrap adapters for SMB connectors or, for the DS-1 card, AMP Champ connectors. EIAs have a 
special backplane cover with cutouts over the cable connectors. 
Use this document in conjunction with the Cisco ONS 15454 Procedure Guide and the Cisco ONS 15454 
Reference Manual 
when working with EIAs or any other system components.
This document contains the following sections:
EIA Naming and Shelf Assembly Compatibility
The procedures in this document refer to A-side and B-side EIAs. As you face the rear of the ONS 15454 
shelf assembly, the right-hand side is considered the A side and the left-hand side is the B side
 
shows the EIA types supported by both the 15454-SA-ANSI and the 15454-SA-HD shelf assemblies.