Технические ссылки для Cisco Cisco ONS 15310-MA SONET Multiservice Platform
13
•
SYNCMSG is the synchronization status message enabled or disabled on the T1 facility. Optional
for ONS 15454 and ONS 15310-CL/MA.
for ONS 15454 and ONS 15310-CL/MA.
•
SENDDUS is the synchronization status message Don’t use for Synchronization (DUS). Optional
for ONS 15454 and ONS 15310-CL/MA, and ONS 15600.
for ONS 15454 and ONS 15310-CL/MA, and ONS 15600.
•
RETIME indicates if retiming is needed. Values are NO or YES. Optional for ONS 15454 and
ONS 15310-CL/MA.
ONS 15310-CL/MA.
•
AISONLPBK is the AIS to be sent on what type of loopback.
•
AISVONAIS is enabled or disabled.
•
AISONLOF is enabled or disabled.
•
MODE type of DS1MODE.
•
SYNCMAP is the synchronization mapping for the DS1 facility. Only supported on ONS 15454.
•
ADMSSM is the administration synchronization status message. Only supported on ONS 15454
and ONS 15600.
and ONS 15600.
•
PROVIDESYNC indicates whether the facility provides synchronization. Only supported on
ONS 15454.
ONS 15454.
•
VTMAP is the port to VT mapping type for that particular STS. Only supported on ONS 15454.
•
INHFELPBK indicates whether far end loopbacks are inhibited on the facility. Only supported on
the ONS 15454.
the ONS 15454.
•
BERTMODE specifies the mode [Test Pattern Generator (TPG) or Test Pattern Monitor (TPM)]
of the port for BERT.
of the port for BERT.
•
BERTPATTERN specifies the error pattern to be injected for BERT.
•
BERTERRCOUNT is the integer value. Value –1 indicates that BERT is disabled/not supported.
•
BERTERRRATE specifies the BERT error rate received.
•
BERTSYNCSTATUS is the synchronization status of BERT values. The parameter type is Y_N,
which specifies if synchronization status is up or down.
which specifies if synchronization status is up or down.
•
PST_PSTQ is primary state.
•
SSTQ is secondary state.
Response Example:
TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-2-1::LINECDE=AMI,FMT=ESF,LBO=0-131,TACC=8,TAPTYPE=DUAL,SOAK=52,SOAKLEF
T=12-25,SFBER=1E-4,SDBER=1E-7,NAME=\"T1
PORT",SYNCMSG=Y,SENDDUS=Y,RETIME=Y,AISONLPBK=ALL,AISVONAIS=Y,AISONLOF=Y,
MODE=FDL,SYNCMAP=ASYNC,ADMSSM=STU,PROVIDESYNC=N,VTMAP=GR253,INHFELP
BK=N,BERTMODE=NONE,BERTPATTERN=NONE,BERTERRCOUNT=,BERTERRRATE=NONE
,BERTSYNCSTATUS=N:OOS-AU,AINS";
;
M 001 COMPLD
"FAC-2-1::LINECDE=AMI,FMT=ESF,LBO=0-131,TACC=8,TAPTYPE=DUAL,SOAK=52,SOAKLEF
T=12-25,SFBER=1E-4,SDBER=1E-7,NAME=\"T1
PORT",SYNCMSG=Y,SENDDUS=Y,RETIME=Y,AISONLPBK=ALL,AISVONAIS=Y,AISONLOF=Y,
MODE=FDL,SYNCMAP=ASYNC,ADMSSM=STU,PROVIDESYNC=N,VTMAP=GR253,INHFELP
BK=N,BERTMODE=NONE,BERTPATTERN=NONE,BERTERRCOUNT=,BERTERRRATE=NONE
,BERTSYNCSTATUS=N:OOS-AU,AINS";
;