Техническая Инструкция для Cisco Cisco Nexus 5010 Switch
FCoE Configuration Between VIC Adapter on UCS
Rack Server and Nexus 5500 Switch
Rack Server and Nexus 5500 Switch
Document ID: 117280
Contributed by Padmanabhan, Cisco TAC Engineer.
Mar 25, 2014
Mar 25, 2014
Contents
Introduction
Prerequisites
Requirements
Components Used
Overview
Step 1: Configure New Setup
Required Features Configuration
Basic vPC Configuration
VSAN Configuration
Step 2: Configure UCS Server and VIC Adapter
Step 3: Configure Nexus 5K Switches for Different Topologies
Topology 1: CNA Ports Directly Connected to Nexus 5K Switch
Overview
Sample Configuration on A Side of Nexus 5K Switch
Verification
Topology 2: FEX Connected to Nexus 5K Switch in Straight−Through Mode and CNA Connected to FEX
Ports
Overview
Sample Configuration
Host vPC Configuration
Verification
Topology 3: FEX Connected to Nexus 5K Switch in Enhanced vPC Mode and CNA Connected to FEX
Ports
Overview
Active − Active FEX Configuration
FCoE Keyword on FEX 102 on B Side of Nexus 5K Switch
Host vPC Configuration
VFC Configuration
Verification
Verify
Troubleshoot
Related Information
Prerequisites
Requirements
Components Used
Overview
Step 1: Configure New Setup
Required Features Configuration
Basic vPC Configuration
VSAN Configuration
Step 2: Configure UCS Server and VIC Adapter
Step 3: Configure Nexus 5K Switches for Different Topologies
Topology 1: CNA Ports Directly Connected to Nexus 5K Switch
Overview
Sample Configuration on A Side of Nexus 5K Switch
Verification
Topology 2: FEX Connected to Nexus 5K Switch in Straight−Through Mode and CNA Connected to FEX
Ports
Overview
Sample Configuration
Host vPC Configuration
Verification
Topology 3: FEX Connected to Nexus 5K Switch in Enhanced vPC Mode and CNA Connected to FEX
Ports
Overview
Active − Active FEX Configuration
FCoE Keyword on FEX 102 on B Side of Nexus 5K Switch
Host vPC Configuration
VFC Configuration
Verification
Verify
Troubleshoot
Related Information
Introduction
This document describes how to configure Fibre Channel over Ethernet (FCoE) connectivity between Virtual
Interface Card (VIC) adapters installed on Cisco Unified Computing System (UCS) rack servers and Cisco
Nexus 5500 (Nexus 5K) Series Switches. Two sample topologies include Cisco Fabric Extender (FEX)
devices, and one sample topology does not.
Interface Card (VIC) adapters installed on Cisco Unified Computing System (UCS) rack servers and Cisco
Nexus 5500 (Nexus 5K) Series Switches. Two sample topologies include Cisco Fabric Extender (FEX)
devices, and one sample topology does not.