Installing and Operating UBIC-V EIAs in the Cisco ONS 15454
78-16140-04
Install the Alignment Standoffs on the ONS 15454 Shelf
Figure 4
Removing a Sheet Metal Cover 
Step 5
Loosen and remove the screw that secures the alarm and timing panel cover to the shelf. Store the alarm 
and timing panel cover for replacement after you install the UBIC-V EIAs.
Install the Alignment Standoffs on the ONS 15454 Shelf
Before you can install the UBIC-V EIAs, you must determine if alignment standoffs are already 
installed. If not, you must install the standoffs.
You will need the following equipment to install the alignment standoffs:
#2 Phillips screwdriver
Small flathead screwdriver 
Alignment standoffs (6) (700-19485-XX)
Step 1
Locate the alignment standoff holes on the shelf assembly where you want to install the UBIC-V EIA(s) 
(
). If alignment standoffs are not installed, go to 
. If alignment standoffs are already 
installed, continue with the 
.