Release Notes for Cisco ONS 15454 Release 7.0.2
OL-11368-01
  Caveats
Maintenance and Administration
Caution
VxWorks is intended for qualified Cisco personnel only. Customer use of VxWorks is not recommended, 
nor is it supported by Cisco's Technical Assistance Center. Inappropriate use of VxWorks commands can 
have a negative and service affecting impact on your network. Please consult the troubleshooting guide 
for your release and platform for appropriate troubleshooting procedures. To exit without logging in, 
enter a Control-D (hold down the Control and D keys at the same time) at the Username prompt. To exit 
after logging in, type “logout” at the VxWorks shell prompt.
Note
CTC does not support adding/creating more than 5 circuits in auto-ranged provisioning. This is as 
designed.
Note
In releases prior to 4.6 you could independently set proxy server gateway settings; however, with Release 
4.6.x and forward, this is no longer the case. To retain the integrity of existing network configurations, 
settings made in a pre-4.6 release are not changed on an upgrade to Release 7.0.x. Current settings are 
displayed in CTC (whether they were inherited from an upgrade, or they were set using the current GUI).
CSCsf30853
A DS3XM-12 card in portless mode does not send DS1 AIS on the DS1 ports when there is an incoming 
DS3 failure, such as DS3 AIS or DS3 MISM. The downstream DS1 facilities alarm is reported as LOF 
rather than AIS. This issue will be resolved in Releases 7.0.4 and 8.0.
CSCsc62845
When you try delete a provisionable patchcord (PPC) from the CTC Provisioning > PPC tab, sometimes 
CTC fails to refresh the screen and the PPC deletion appears to have failed. The workaround is to restart 
into CTC. This issue is resolved in Release 7.2.
CSCsc00811
Deleting a monitor circuit and its parent at the same time might result in a PARTIAL parent circuit. To 
avoid this, delete the monitor circuit before deleting the parent circuit. This issue will not be resolved
CSCsc36281
The software Activating progress popup window might fail to automatically close during multiple or 
parallel software activations. If this occurs you must manually close the popup window. The following 
error message might also be raised and need to be closed: 
“EID-3251 Unable to complete requested action. Unable to activate because the working software 
version is newer than the protect one.” 
To ensure that all nodes are using the correct software version you should close and restart CTC. This 
issue will be resolved in a future release.