Технические ссылки для Cisco Cisco TelePresence MX700

Скачать
Страница из 205
D15335.04
 Cisco TelePresence MX700 and MX800 API Reference Guide CE8.2, JUNE 2016. 
Copyright © 2016 Cisco Systems, Inc. All rights reserved. 
86
Cisco TelePresence MX700 and MX800
API Reference Guide
SerialPort configuration
xConfiguration SerialPort Mode
Enable/disable the serial port (COM port).
Requires user role: ADMIN
Default value: On
USAGE:
xConfiguration SerialPort Mode: 
Mode
where
Mode
: Off/On
Off: Disable the serial port.
On: Enable the serial port.
xConfiguration SerialPort BaudRate
Define the baud rate (data transmission rate, bits per second) for the serial port. The default 
value is 115200. 
Other connection parameters for the serial port are: Data bits: 8; Parity: None; Stop bits: 1; Flow 
control: None.
Requires user role: ADMIN
Default value: 115200
USAGE:
xConfiguration SerialPort BaudRate: 
BaudRate
where
BaudRate
: 9600/19200/38400/57600/115200
Set a baud rate from the baud rates listed (bps).
xConfiguration SerialPort LoginRequired
Define if login shall be required when connecting to the serial port.
Requires user role: ADMIN
Default value: On
USAGE:
xConfiguration SerialPort LoginRequired: 
LoginRequired
where
LoginRequired
: Off/On
Off: The user can access the codec via the serial port without any login.
On: Login is required when connecting to the codec via the serial port.