Appendix F Component Mounting Conditions 
F.5 
NIC (Network Interface Card) 
76 
 
C122-E175-01EN 
DIMM mounting order 
The order of DIMM installation is shown below. 
 
In below table, DIMMs are installed in order from one with small number. 
TABLE F.5 DIMM mounting order in special case in SB 
 
CPU#0 
CPU#1 
DIMM 
Slot# 
0A0  0A3  0B0  0B3  0C0  0C3  0D0  0D3  1A0  1A3  1B0  1B3  1C0  1C3  1D0  0D3 
0A1  0A4  0B1  0B4  0C1  0C4  0D1  0D4  1A1  1A4  1B1  1B4  1C1  1C4  1D1  0D4 
0A2  0A5  0B2  0B5  0C2  0C5  0D2  0D5  1A2  1A5  1B2  1B5  1C2  1C5  1D2  0D5 
Normal 
12  12  10  10  14 
14 
13  13  11  11  15  15 
16  16  20  20  18  18  22 
22 
17  17  21  21  19  19  23  23 
Full or 
Partial 
Mirror 
10  10  10 
10 
11  11  11  11 
Spare 
 
F.3 
Available internal I/O ports 
The following table lists the number of available internal I/O ports. 
TABLE F.6 Available internal I/O ports and the quantities 
Internal I/O 
No. 
Remarks 
SB 
USB 
SB#0 only 
VGA 
SB#0 only 
IOU_1GbE 
GbE 
 
IOU_10GbE 
10GbE 
DU 
HDD/SSD 
 
F.4 
Legacy BIOS Compatibility (CSM) 
The Cisco C880 server uses the UEFI, which is firmware that provides the BIOS emulation function. Currently, 
the following legacy BIOS restrictions are known: 
Option ROM area restriction: The number of PXE-enabled cards that can operate as boot devices is 
restricted to four. 
I/O space restriction: In a legacy BIOS environment, I/O space is required on a boot device. 
Note 
In a CSM environment, I/O space must be allocated to a boot device. 
F.5 
NIC (Network Interface Card) 
Note the following precautions on mounting of a NIC (network interface card). 
Notes 
We recommend specifying the members of teaming between LANs of the same type. (We recommend 
teaming between cards of the same type in the onboard LAN.) 
If the teaming is specified with different types of LAN, the scaling function on the receive side may be off 
because of differences in the scaling function. 
Consequently, the balance of receive traffic may not be optimized, but this is not a problem for normal 
operation. 
Depending on the Intel PROSet version used at the time of teaming configuration, a warning may be 
output about scaling on the receive side being disabled for the above-described reasons. In this event, 
simply click the [OK] button. 
For details on the scaling function on the receive side or other precautions, see the help for Intel PROSet