Руководство По Установке для Cisco Cisco C880 M4 Server

Скачать
Страница из 25
 
13 
 
2.2 
Power cable connection 
Input power system of Cisco C880 Server is described in this section. 
2.2.1  Power Cables Connections 
This section shows the figure of input power of Cisco C880 Server. 
 
Standard  Configuration  of  200  V  (Single  power  feed  and  no  Redundant  Power  Feed) 
with Power Distribution Box Connection 
It is necessary to arrange three PSUs, three FANUs, three power cables (200 V IEC60320 C20) and two 
power distribution box (200 V IEC60320 C19×3type) for 200 V standard configuration.  
When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution 
panel. See “
.” 
 
FIGURE 2.9 200V Standard Configuration (single power feed and no redundant power feed) with Power 
Distribution Box Connection 
 
Number 
Description 
(1) 
Power distribution box (200V C 19  3 type)