Белая книга для Cisco Cisco UCS C22 M3 Rack Server

Скачать
Страница из 23
 
 
© 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. 
Page 1 of 23 
White Paper 
Cisco UCS C240 M4 I/O Characterization  
Executive Summary 
This document outlines the I/O performance characteristics of the Cisco UCS
®
 C240 M4 Rack Server using the 
Cisco
®
 12-Gbps SAS modular RAID controller (UCSC-MRAID12G). Performance comparisons of various serial-
attached Small Computer System Interface (SCSI; SAS) hard-disk drives (HDDs), solid-state drives (SSDs), 
Redundant Array of Independent Disk (RAID) configurations, and controller options are presented. This white 
paper aims to assist customers in making well-informed decisions in choosing the right internal disk types and 
configuring the right controller options and RAID levels to meet their individual I/O workload needs. 
Performance data was obtained using the Iometer measurement tool, with analysis based on the metrics of 
input/output operations per second (IOPS) for random I/O workloads, and megabytes per second (MBps) 
throughput for sequential I/O workloads. From this analysis, specific recommendations are made for storage 
configuration parameters. 
Many combinations of different drive types and RAID levels are possible. For these characterization tests, 
performance evaluations were limited to 7200-rpm small form factor (SFF) HDDs, 10,000-rpm SFF HDDs, and SFF 
SSD drive types, with configurations of RAID 0, RAID 5, and RAID 10 virtual disks. 
Tables 1 and 2 list the recommended virtual drive configuration parameters for deployment of SSDs and HDDs. 
Table 1. 
Recommended Virtual Drive Configuration Parameters for Solid-State Drives 
Workload 
RAID Level 
Strip Size 
Disk Cache Policy 
I/O Cache Policy 
Read Policy 
Write Policy 
Random I/O 
RAID 0 
256 KB 
Disabled 
Direct 
Normal Read 
Write Through 
Random I/O 
RAID 10 
256 KB 
Disabled 
Direct 
Normal Read 
Write Through 
Random I/O 
RAID 5 
256 KB 
Disabled 
Direct 
Normal Read 
Write Through 
Sequential I/O 
RAID 0 
256 KB 
Disabled 
Direct 
Normal Read 
Write Through 
Sequential I/O 
RAID 10 
256 KB 
Disabled 
Direct 
Normal Read 
Write Through 
Sequential I/O 
RAID 5 
256 KB 
Disabled 
Direct 
Normal Read 
Write Through 
Table 2. 
Recommended Virtual Drive Configuration Parameters for Hard-Disk Drives 
Workload 
RAID Level 
Strip Size 
Disk Cache Policy 
I/O Cache Policy 
Read Policy 
Write Policy 
Random I/O 
RAID 0 
256 KB 
Disabled 
Cached 
Read Ahead 
Write Back w/BBU 
Random I/O 
RAID 10 
256 KB 
Disabled 
Cached 
Read Ahead 
Write Back w/BBU 
Random I/O 
RAID 5 
256 KB 
Disabled 
Cached 
Read Ahead 
Write Back w/BBU 
Sequential I/O 
RAID 0 
256 KB 
Disabled 
Cached 
Read Ahead 
Write Back w/BBU 
Sequential I/O 
RAID 10 
256 KB 
Disabled 
Cached 
Read Ahead 
Write Back w/BBU 
Sequential I/O 