Receiver Parameters for GS7000 Nodes 
 
 
143 
 
Parameter 
Name (LCI) 
ICIM 
Abbreviation 
Description 
Values 
Default 
Mode Select 
Mode 
Module redundancy control. If set 
to Master, the unit is only 
controlled by the Enable control. 
If set to Slave, the unit is controlled 
by the Enable control and the 
external input CNT_IN. 
If set to Single, Rx1 to Rx4 will 
continue to operate (i.e. not switch) 
even if the optical input level falls 
below the major alarm threshold. 
0: Slave 
1: Single 
2: Master 
Single 
Enable 1 
Enable 2 
Enable 3 
Enable 4 
Enable1 
Enable2 
Enable3 
Enable4 
Enables or disables Rx1 to Rx4. If 
set to Off, the receiver is muted (RF 
amplifier turned off), alarms are 
inhibited, and redundancy is turned 
off. 
0: Off   
1: On 
On 
Rx Input 1 Enable 
Rx Input 2 Enable 
Rx Input 3 Enable 
Rx Input 4 Enable 
Rx1Inp1 
Rx1Inp2 
Rx2Inp1 
Rx2Inp2 
Defines the initial status of the Rx1 
or Rx2 RF Output mute controls. If 
On, the output is muted. However, 
the alarm can override the initial 
status and change the mute setting. 
0 = Both off 
1 = A only 
2 = B only 
3 = Both on 
Both On 
RF Atten 1 
RF Atten 2 
RFAtten1 
RFAtten2 
Sets the RF attenuation for output 1 
or output 2. 
Note: In one RF output operation 
mode, RF Atten 1 controls the 
combined RF signal for input 1 and 
input 3 , RF Atten 2 controls the 
combined RF signal for input 2 and 
input 4. 
0 to 10 dB in 0.5 
dB steps 
0 dB 
Manual Alarm
1 2
  Alarm
1
 
Force alarm if the Enable control is 
On. 
0: Off 
1: On 
Off