Справочник Пользователя для Integral INSSD64GP25MXZ

Скачать
Страница из 25
 
 
 
 
-CBLID(Cable assembly 
type identify) 
 
 
37, 38 
-CS0, -CS1(Chip select)  I 
These signals are used to select 
the Command Block and Control 
Block registers. When –DMACK is 
asserted, -Cs0 and –Cs1 shall be 
negated and transfers shall be 
16-bit wide. 
39 
-DASP(Device active, 
Device 1 present) 
I/O 
During the reset protocol, -DASP 
shall be asserted by Device 1 to 
indicate that the device is present. 
41, 42 
VCC 
Power supply 
02, 19, 22, 24, 
26, 30, 40, 43 
GND 
-- 
Ground. 
*Note: 
“I”   
 
An input from the host system to the device. 
“O”   
 
An output from the device to the host system. 
“I/O”  
 
An input/output(bi-direction) common. 
“P”   
 
Power supply. 
 
3.0  Electrical Characteristics 
3.1  Absolute Maximum Rating 
 
Ite
Symbol  Parameter 
MIN 
MAX 
Unit 
V
DD
-V
SS
 
DC Power Supply 
-0.3 
+5.5 
VIN 
Input Voltage 
Vss-0.3 
V
DD
+0.3 
Ta 
Commercial Operating 
Temperature   
+70 
0
Tst 
Commercial Storage 
Temperature 
-25 
+85 
0
Ta 
Industrial Operating 
Temperature   
-40 
+85 
0
Tst 
Industrial Storage 
Temperature 
-40 
+85 
0
 
Parameter 
Symbol 
MIN 
TYP 
MAX 
Unit 
3.0 
3.3 
3.6 
V
DD
 Voltage 
V
DD
 
4.5 
5.0 
5.5