3.4  Power Management 
 
System Power Consumption:                               
(Ta = 0 to 70
0
C)
                  
 
 
Symbol 
Parameter 
Conditions 
MIN 
TYP 
MAX 
Unit 
Iccr 
Read current 
5V 
150 
mA 
Iccw 
Write current 
5V 
130 
mA 
Ipd 
Power down current 
5V 
12 
 
mA 
Iccr 
Read current 
3.3V 
230 
mA 
Iccw 
Write current 
3.3V 
200 
mA 
Ipd 
Power down current 
3.3V 
18 
 
mA 
Note: Test Based on 8 pieces of TSOP flash.     
4.0  Software Interface 
4.1  ATA Task File Registers 
The I/O decoding of each register is as follows   
 
-CS1  -CS0 
A2 
A1 
A0 
-DIOR=0(-DIOW=1) 
-DIOW=0(-DIOR=1) 
Data(Read) 
Data(Write) 
Error 
Feature 
Sector Count 
Sector Count 
Sector Number (LBA7-0) 
Sector Number (LBA7-0) 
Cylinder Low (LBA 15-8) 
Cylinder Low (LBA 15-8) 
Cylinder High (LBA 23-16) 
Cylinder High(LBA 23-16) 
Drive/Head (LBA 27-24) 
Drive/Head (LBA 27-24) 
Status 
Command 
Alternate Status 
Device Control 
Drive Address 
Reserved