Техническая Спецификация для Cisco Cisco UCS C250 M1 Extended-Memory Rack-Mount Server

Скачать
Страница из 100
Cisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
96
Power supply standby voltage 
12 VDC
Efficiency rating 
> 92% at 50% Load
Form Factor
RSP1
Input connector
3 wire Connector (Molex MINIFIT SR. R/A )
Table 56  UCS C240 M4 LFF Power Specifications (1200 W V2 AC power supply)
Description
Specification
AC input voltage
Voltage Range 100-127 VAC, 200-240 VAC nominal 
 
(range: 90-140 VAC, 180-264 VAC)
AC input frequency
50 to 60 Hz nominal 
 
(range: 47 to 63 Hz)
Max AC Input current 
11 A at 100 VAC
7 A  at 200 VAC
Maximum Input VA
1400 V\A @230VAC
Maximum output power per power 
supply
800 W  at 100 - 120 VAC
1200 W at 200 - 240 VAC
36 W on 12V DC Standby
Maximum inrush current
30 A (sub cycle duration)
Maximum hold up time
12 ms @ 1200 W
Power supply output voltage
12 VDC
Power supply standby voltage 
12 VDC
Efficiency rating 
Climate Savers Platinum Efficiency (80Plus Platinum Certified)
Form Factor
RSP1 (C-Series 2U and 4U Server)
Input connector
IEC320 C14
Table 55  UCS C240 M4 LFF Power Specifications (930 W DC V2 power supply)  (continued)
Description