Руководство По Обслуживанию для Cisco Cisco TelePresence MX700
D15331.01 MX700 and MX800 Administrator Guide CE8.0, NOVEMBER 2015.
www.cisco.com — Copyright © 2015 Cisco Systems, Inc. All rights reserved.
141
Cisco TelePresence MX700 and MX800
Administrator Guide
High: Requires nearly optimal video conferencing lighting conditions and a good quality
video input in order to achieve a good overall experience. Rather high resolutions will be
used.
Video Input Connector [1..5] OptimalDefinition Threshold60fps
For each video input, this setting tells the system the lowest resolution where it should
transmit 60fps. So for all resolutions lower than this, the maximum transmitted frame rate
would be 30fps, while above this resolution 60fps would also be possible, if the available
bandwidth is adequate.
Requires user role: ADMIN
Default value: 1280_720
Default value: 1280_720
Value space: 512_288/768_448/1024_576/1280_720/1920_1080/Never
512_288: Set the threshold to 512x288.
768_448: Set the threshold to 768x448.
1024_576: Set the threshold to 1024x576.
1280_720: Set the threshold to 1280x720.
1920_1080: Set the threshold to 1920x1080.
Never: Do not set a threshold for transmitting 60fps.
768_448: Set the threshold to 768x448.
1024_576: Set the threshold to 1024x576.
1280_720: Set the threshold to 1280x720.
1920_1080: Set the threshold to 1920x1080.
Never: Do not set a threshold for transmitting 60fps.
Video Input Connector [1..4] PresentationSelection
Define how the video system will behave when you connect a presentation source to the
video input. In general, any input source can be used as a presentation source; normally,
the main camera will not be used as a presentation source.
If the video system is in standby mode, it will wake up when you connect a presentation
If the video system is in standby mode, it will wake up when you connect a presentation
source. Note that sharing the presentation with the far end always requires additional action
(press Share on the user interface).
Requires user role: ADMIN
Default value: Connector 1: Manual Connector 2: OnConnect for single camera system,
Default value: Connector 1: Manual Connector 2: OnConnect for single camera system,
Manual for dual camera systems Connector 3, 4: OnConnect
Value space: Connector 1: Manual Connector 2: Manual/OnConnect for single camera
systems, and Manual for dual camera systems Connector 3, 4: Manual/OnConnect
Manual: In manual mode, the contents of the video input will not be presented on the
screen until you choose it from the user interface.
OnConnect: When in on-connect mode, the content on the video input will be presented
OnConnect: When in on-connect mode, the content on the video input will be presented
on screen when a cable is connected. Otherwise, the behavior is the same as in manual
mode.
Video Input Connector [1..4] RGBQuantizationRange
The devices connected to the video input should follow the rules for RGB video quantization
range defined in CEA-861. Unfortunately some devices do not follow the standard and this
configuration may be used to override the settings to get a perfect image with any source.
Requires user role: ADMIN
Default value: Connector 1, 2, 3: Auto Connector 4: Full
Default value: Connector 1, 2, 3: Auto Connector 4: Full
Value space: Auto/Full/Limited
Auto: RGB quantization range is automatically selected based on video format according
to CEA-861-E. CE video formats will use limited quantization range levels. IT video
formats will use full quantization range levels.
Full: Full quantization range. The R, G, B quantization range includes all code values (0 -
Full: Full quantization range. The R, G, B quantization range includes all code values (0 -
255). This is defined in CEA-861-E.
Limited: Limited Quantization Range. R, G, B quantization range that excludes some code
Limited: Limited Quantization Range. R, G, B quantization range that excludes some code
values at the extremes (16 - 235). This is defined in CEA-861-E.
Introduction
Configuration
Peripherals
Maintenance
System settings
Appendices
System settings