Руководство По Обслуживанию для Cisco Cisco TelePresence MX700

Скачать
Страница из 124
D14850.10 MX200 and MX300 Administrator Guide TC7.2, AUGUST 2014.  
www.cisco.com — Copyright © 2011–2014 Cisco Systems, Inc. All rights reserved. 
83
Cisco TelePresence MX200 and MX300  
Administrator Guide
Peripherals settings
Peripherals Pairing CiscoTouchPanels RemotePairing
Not applicable.
Requires user role: ADMIN
Value space: <Off/On>
Off: Remote pairing of Touch 10 is not allowed.
On: Remote pairing of Touch 10 is allowed.
Example:
 Peripherals Pairing CiscoTouchPanels RemotePairing: On
Peripherals Profile TouchPanels
Set the number of touch panels that are expected to be connected to the video system. This 
information is used by the video system’s diagnostics service. If the number of connected touch 
panels does not match this setting, the diagnostics service will report it as an inconsistency. 
Note that only one Cisco Touch controller is supported in this version.
Requires user role: ADMIN
Value space: <NotSet/Minimum1/0/1/2/3/4/5>
NotSet: No touch panel check is performed.
Minimum1: At least one touch panel should be connected to the video system.  
0-5: This number of Touch controllers should be connected to the video system. 
Example:
 Peripherals Profile TouchPanels: NotSet