Примечания к выпуску для Cisco Cisco Firepower Management Center 2000
21
FireSIGHT System Release Notes
Resolved Issues
Improved error message warning against use of overlapping port settings in DCE/RPC advanced settings.
(CSCuu18577)
(CSCuu18577)
Resolved an issue where connectivity to the AMP cloud may be lost after using the system for an extended period
of time. (CSCuu24587)
of time. (CSCuu24587)
Resolved an issue where the system experienced a disruption in traffic if you created a link aggregation group (LAG)
on a physical Series 3 device connected to a Cisco Nexus 7000 switch. (CSCuu31626)
on a physical Series 3 device connected to a Cisco Nexus 7000 switch. (CSCuu31626)
Resolved an issue where, if you changed your system's time zone to a zone east of UTC and added a correlation rule
with at least one inactive period to a correlation policy, policy apply failed. (CSCuu37600)
with at least one inactive period to a correlation policy, policy apply failed. (CSCuu37600)
Resolved an issue where creating a routed interface on your clustered Series 3 device caused connectivity issues.
(CSCuu37668)
(CSCuu37668)
Resolved an issue where the Send email check box on the Report Templates tab of the Reporting page did not stay
selected if you generated a report, navigated away from the Report Templates tab, and then generated another
report. (CSCuu41580, CSCuu97750)
selected if you generated a report, navigated away from the Report Templates tab, and then generated another
report. (CSCuu41580, CSCuu97750)
Improved tracking of the number of monitored hosts. (CSCuu77263)
Resolved an issue where, if you configured your Defense Center to use a static IPv4 address with an IPv6 address
enabled and you accessed the Defense Center's interface using the IPv6 address, the Access Control Policy page
did not load. (CSCuu83933)
enabled and you accessed the Defense Center's interface using the IPv6 address, the Access Control Policy page
did not load. (CSCuu83933)
Resolved an issue where, in rare cases, your system appeared unstable and did not recover from a hard reset.
(CSCuu93154)
(CSCuu93154)
Resolved an issue where a drive failure on some DC4000 appliances caused RAID controller failure and data loss.
(CSCuu93159)
(CSCuu93159)
Resolved an issue where the Product Licensing dashboard widget did not list any URL Filtering licenses even if URL
Filtering licenses were present. (CSCuu97762)
Filtering licenses were present. (CSCuu97762)
Improved SFDatacorrelator performance. (CSCuv48373)
Issues Resolved in Previous Versions
Previously resolved issues are listed by version.
Issues resolved in Version 5.4.0.3 and Version 5.4.1.2:
Security Issue
Addressed multiple vulnerabilities in SSLv3 that allowed external attacks on client connections, as
described in CVE-2015-0286,CVE-2015-0287, CVE-2015-0289, CVE-2015-0292, and CVE-2015-0293.
Security Issue
Addressed a cross-site scripting (XSS) vulnerability, as described in CVE-2015-0707.
Security Issue
Addressed multiple vulnerability issues in Linux and other third parties, as described in
CVE-2011-2699, CVE-2012-2744, CVE-2012-3400, and CVE-2015-1781.
Security Issue
Addressed a vulnerability in HTTP connection handling that allowed users to be redirected to
malicious websites, as described in CVE-2015-0706.
Security Issue
Resolved an issue where the system can experience a microengine fault based on malformed packet
data in traffic inspected by a FirePOWER 7000 or 8000 Series managed device. (CSCuu10871, CSCuu26678)
When routing is configured on a Series 3 device, the system may forward source-routing IPv4 packets, which direct
the packet along a different path than configured on the router and can be used to bypass network security
measures. (132121/CSCze88520)
the packet along a different path than configured on the router and can be used to bypass network security
measures. (132121/CSCze88520)