11-97
Cisco IronPort AsyncOS 7.2.0 for Security Management User Guide
OL-21768-01
Chapter 11      Common Administrative Tasks
Empty Versus Omitted Tags
Use caution when uploading or pasting sections of configuration files. If you do 
not include a tag, then its value in the configuration is not modified when you load 
a configuration file. However, if you include an empty tag, then its configuration 
setting is cleared.
For example, uploading the following code removes all listeners from the system: 
Warning
When uploading or pasting subsections of a configuration file, you can 
disconnect yourself from the GUI or CLI and destroy large amounts of 
configuration data. Do not disable services with this command if you are not 
able to reconnect to the appliance using another protocol, the Serial interface, 
or the default settings on the Management port. Also, do not use this command 
if you are unsure of the exact configuration syntax as defined by the DTD. 
Always back up the configuration data before loading a new configuration file. 
Note About Loading Passwords for Log Subscriptions
If you attempt to load a configuration file that contains a log subscription that 
requires a password (for example, one that will use FTP push), the 
loadconfig
 
command does not warn you about the missing password. The FTP push fails and 
alerts are generated until you configure the correct password using the 
logconfig
 
command. 
Note About Character Set Encoding 
The “encoding” attribute of the XML configuration file must be “
ISO-8859-1
” 
regardless of the character set you may be using to manipulate the file offline. The 
encoding attribute is specified in the file whenever you issue the 
showconfig
saveconfig
, or 
mailconfig
 command: 
Currently, only configuration files with this encoding can be loaded. 
<listeners></listeners>
<?xml version="1.0" encoding="ISO-8859-1"?>