Errata 
 
 
Specification Update 
 
93 
AH6P 
Activation of Intel
®
 Adaptive Thermal Monitor While Intel
®
 Dynamic 
Front Side Bus Frequency Switching Is Active May Lead to an 
Incorrect Operating Point Frequency 
Problem: 
Intel Adaptive Thermal Monitor has the ability to use multiple frequency/voltage 
operating points to cool the processor while maintaining a high level of 
performance. If Intel Dynamic Front Side Bus Frequency Switching is active, activation 
of the Intel Adaptive Thermal Monitor may transition the processor to the correct 
operating point voltage, but not frequency.  
This may occur if: 
1.) The software/OS requests to go to a higher performance Enhanced Intel 
SpeedStep
®
 Technology operating point during the thermal monitor activation 
period. 
2.) An entry into C4 state or Intel Enhanced Deeper Sleep interrupts the 
transition between the Intel Dynamic Front Side Bus Frequency Switching 
frequency and the targeted thermal monitor operating point frequency.  
Implication:  If this erratum occurs, the Intel Dynamic Front Side Bus Frequency Switching 
operating point frequency will be observed along with the Intel Adaptive Thermal 
Monitor operating point voltage. The performance state status register 
(IA32_PERF_STS) will reflect this intermediate performance state. There is no 
functional impact; the eventual voltage/frequency selection is a valid operating point. 
De-activation of the Intel Adaptive Thermal Monitor will result in the processor 
transitioning to the expected Enhanced Intel SpeedStep Technology operating point. 
Workaround:  None Identified 
Status: 
For the affected steppings, see the Summary Tables of Changes