Thermal Specifications and Design Considerations
5
Thermal Specifications and 
Design Considerations
Maintaining the proper thermal environment is key to reliable, long-term system 
operation. A complete thermal solution includes both component and system level 
thermal management features. The system/processor thermal solution should be 
designed so that the processor remains within the minimum and maximum junction 
temperature (Tj) specifications at the corresponding thermal design power (TDP) value 
listed in 
 through 
Caution:
Operating the processor outside these limits may result in permanent damage to the 
processor and potentially other components in the system. 
NOTES:
1.
The TDP specification should be used to design the processor thermal solution. The TDP is not the 
maximum theoretical power the processor can generate. 
2.
Not 100% tested. These power specifications are determined by characterization of the processor currents 
at higher temperatures and extrapolating the values for the temperature indicated.
3.
As measured by the activation of the on-die Intel Thermal Monitor. The Intel Thermal Monitor’s automatic 
mode is used to indicate that the maximum T
J
 has been reached. Refer to 
 for details.
4.
The Intel Thermal Monitor automatic mode must be enabled for the processor to operate within 
specifications. 
Table 19.
Power Specifications for the Intel Core 2 Duo Processor - Standard Voltage
Symbol
Processor 
Number
Core Frequency & Voltage
Thermal Design 
Power
Unit
Notes
TDP
T7800
T7700
T7500
T7300
T7250
T7100
2.6 GHz & HFM V
CC
2.4 GHz & HFM V
CC
2.2 GHz & HFM V
CC
2.0 GHz & HFM V
CC
2.0 GHz & HFM V
CC
1.8 GHz & HFM V
CC
1.2 GHZ & LFM V
CC
0.80 GHZ & SuperLFM V
CC
35
35
35
35
35
35
25
12
W
1, 4, 5, 6, 9
1, 4, 5, 6, 9
1, 4, 5, 6, 9
1, 4, 5, 6, 10
Symbol
Parameter
Min
Typ
Max
Unit
P
AH,
P
SGNT
Auto Halt, Stop Grant Power
at HFM V
CC
at SuperLFM V
CC
13.5
6.9
W
2,  5,  7
P
SLP
Sleep Power 
at HFM V
CC
at SuperLFM V
CC
12.9
6.7
W
2,  5,  7
P
DSLP
Deep Sleep Power 
at HFM V
CC
at SuperLFM V
CC
7.7
4.3
W
2,  5,  8
P
DPRSLP
Deeper Sleep Power
2.0
W
2, 8
P
DC4
Intel® Enhanced Deeper Sleep Power
1.2
W
2, 8
T
J
Junction Temperature
0
100
°C
3,  4