Примечания к выпуску для Cisco Cisco IOS XR Software Release 3.2

Скачать
Страница из 28
15
Release Notes for Cisco IOS XR Software Release 3.2.3
OL-8819-02
SFC-160,GSR12810 Switch Fabric Card(10) OC-768 107
GSR16/80-CSC Cisco 12016 80 Gbps GSR Clock Scheduler Card 43
GSR16/80-SFC Cisco 12016 80 Gbps GSR Switch Fabric Card 35
GSR16/320-CSC Cisco 12416 320 Gbps GSR Clock Scheduler Card 106
GSR16/320-SFC Cisco 12416 320 Gbps Switch Fabric Card 93
CSC-256,GSR12816 Clock Scheduler Card(16) OC-768 177
SFC-256,GSR12816 Switch Fabric Card(16) OC-768 151
GSR04-FABRIC Alarm Board(404) 208
GSR6-ALRM GSR 12406 Alarm Module 26
GSR10-ALRM GSR 12410 Alarm Module 33
GSR16-ALRM Cisco 12016 Alarm Module 35
GSR6-BLOWER GSR 12406 Blower Module 178
GSR16-BLOWER GSR 12016 Blower Module 178
Bus Board(16) 20
RP/0/0/CPU0:c12k# 
If you plan to insert a new card, locate the entry for the card to be inserted and note the power it 
consumes. If this power is less than the figure given in Worst Case Redundant Power Available (the 
figure displayed in the show environment power-supply table command output), the card can be safely 
inserted. As long as the Worst Case Redundant Power Available is not zero, a PEM can be powered down 
for replacement without impact.
Note
No alerts are issued if more cards are inserted than the PEMs can support. You are responsible for 
determining the power budget for the chassis before you change it. Exceeding the power budget can 
result in the PEM being overloaded and cards powering down due to insufficient available power.
Caveats
Caveats describe unexpected behavior in Cisco IOS XR software. A severity 1 caveat is the most 
serious; a severity 2 caveat is less serious. This section lists resolved and open relevant caveats.
Resolved Caveats
The following caveats from prior releases have been resolved in Cisco IOS XR Software Release 3.2.3. 
CSCsc22711
Brief Description: cctl_server process exits after upgrade
Conditions: During an upgrade (release 3.2.x to 3.2.y), a cctl_server process crash might occur on 
a linecard. The upgrade completes successfully, and the process restarts.
Workaround: none
CSCej51953
Brief Description: Configuration commit list is deleted after a power cycle.
Symptoms: In rare circumstances, the configuration commit list is cleared after a system reload. 
The following error message is reported:
'cfgmgr-rp[133]: %MGBL-CFGMGR-3-BOOT_ERROR: 'sysdb' detected the 'warning' condition 
'A SysDB client tried to access a nonexistent item or list an empty directory' 
Conditions: Configuration Manager was unable to use the previously saved commit points. All 
saved commit points in the commit database are removed.