  Installation Notes
Step 21
Reenable your 802.11a and 802.11b/g networks.
Step 22
If desired, reload your latest configuration file to the controller.
Step 23
To verify that the 6.0.202.0 controller software is installed on your controller, click Monitor on the 
controller GUI and look at the Software Version field under Controller Summary.
Step 24
To verify that the Cisco Unified Wireless Network Controller Boot Software 5.2.157.0 ER.aes file is 
installed on your controller, enter the show sysinfo command on the controller CLI and look at the 
Emergency Image Version field. 
Note
If you do not install the 5.2.157.0 ER.aes file, the Emergency Image Version field shows “N/A.”
Installation Notes
This section contains important information to keep in mind when installing controllers and access 
points.
Warnings
Warning
This warning means danger. You are in a situation that could cause bodily injury. Before you work on 
any equipment, be aware of the hazards involved with electrical circuitry and be familiar with 
standard practices for preventing accidents. Use the statement number provided at the end of each 
warning to locate its translation in the translated safety warnings that accompanied this device. 
Statement 1071
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 
Statement 1030
Warning
Do not locate the antenna near overhead power lines or other electric light or power circuits, or 
where it can come into contact with such circuits. When installing the antenna, take extreme care 
not to come into contact with such circuits, as they may cause serious injury or death. For proper 
installation and grounding of the antenna, please refer to national and local codes (e.g. U.S.: NFPA 70, 
National Electrical Code, Article 810, Canada: Canadian Electrical Code, Section 54). 
Statement 280
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that 
a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the 
phase conductors (all current-carrying conductors). 
Statement 13