Release Note для Cisco Cisco TelePresence MX700
Cisco TelePresence systems hardware dependencies
Cisco TelePresence System C/EX/SX/MX Series Software Release Notes
Page 189 of 194
Using the xAPI / tshell to identify software limitations
Executing the API command xStatus SystemUnit Hardware Module CompatibilityLevel will reveal
if there are any software constraints for the system.
if there are any software constraints for the system.
The result returned when running the command will be 0, 1, 2, 3, 4, v, 1v, 2v or 4v:
Compatibility
level
level
Applicable
systems
systems
Description
Minimum software version
TC4
1)
TC5
3)
TC6
TC7
0
All except
MX200 G2
MX200 G2
No restrictions
All
All
All
All
0
MX300 G2
Product was
introduced with
TC7.0.0
introduced with
TC7.0.0
None
None
None
7.0.0
1
All
The system has the
new flash memory
installed
new flash memory
installed
4.2.0
All
All
All
2
EX/MX
The system has the
new flash memory and
the new E4 sensor
new flash memory and
the new E4 sensor
4.2.4
5.1.6
2)
All
All
2
SX20
Product was
introduced with
TC5.1.0
introduced with
TC5.1.0
None
5.1.0
All
All
2
C20
A new hardware
revision, minor change
revision, minor change
4.2.3
5.1.1
All
All
3
SX20
A new hardware
revision, minor change
revision, minor change
None
5.1.6
All
All
3
C40
A new hardware
revision, minor change
revision, minor change
4.2.4
5.1.5
All
All
V
MX300
Product was
introduced with
TC5.0.1
introduced with
TC5.0.1
None
5.0.1
All
All
1V
MX300
NAND flash version 1.
Minimum software
version TC5.1.0.
Minimum software
version TC5.1.0.
None
5.1.0
All
All
2V
MX300
NAND flash version 1
and E4 sensor.
and E4 sensor.
None
5.1.6
2)
All
All
4
All TC EPs
except
SX20/MX300G2
except
SX20/MX300G2
NAND flash version 2
None
5.1.11
6.2.2 /
6.3.0
6.3.0
All
1)
Although listed in this table TC4 is no longer supported and should not be used by any customer.
2)
Although TC5.1.1 can be installed, Cisco recommends TC5.1.6 due to major color calibration
improvements for MX series with the E4 sensor. CSCud31649.
3)
TC5 will shortly be end of support; customers should migrate to TC6 or TC7.