Cisco Aironet Series 1600/2600/3600 Access Point Deployment Guide, Release 7.5
 
  Unique Installations
Stadium/Harsh Environments
Customers wishing to install the AP in harsh environments where it may be exposed to weather, such as 
sporting areas, stadiums, open garden areas or warehouse freezers, may wish to use a NEMA type 
enclosure.
Figure 26
Example of NEMA 16x14x8 Enclosure with pressure vent on bottom 
Third-party sources for NEMA type enclosures include:
When using a NEMA type enclosure, try to have the cables exit out of the bottom of the enclosure so 
that rain and moisture do not run down the cable into the enclosure. Also, the color of the enclosure may 
affect the heat rating; for example, a black enclosure gets much hotter in the sun than a white one. You 
may also want to use a pressure vent to prevent moisture accumulation. Se
.
Areas with High Vibration
If the Access Point is installed using a “side arm” type mount or other mounting locations where there 
is a likelihood of high vibration, it is recommended that a padlock or metal pin be used to prevent the 
AP from vibrating loose from the bracket.