Дорожная карта для Cisco Cisco Packet Data Gateway (PDG)

Скачать
Страница из 982
Packet Data Interworking Function Overview   
▀  Features and Functionality - Licensed Enhanced Feature Support 
 
▄  Cisco ASR 5000 Series Product Overview 
OL-22938-01   
configures result code 5003 to mean terminate the session immediately. 
In this scenario, the PDIF receives the DEA from an HSS with the failure code 5003 to terminate the IKE setup for the 
session. The PDIF sends the IKE_AUTH Response containing a Notify Payload with the type as AUTH_FAILED plus 
the EAP payload if one was received in the DEA. 
When the PDIF received the last DEA message with AVPs that are not in the dictionary, and with the M-bit set to 1, the 
PDIF disconnects the session. 
Important:
  Refer to Configuring Diameter Authentication Failure Handling in the AAA Interface Administration 
and Reference and the Command Line Interface Reference for more information. 
 
Online Upgrade 
The customer has the benefits of upgrading software from a fully redundant device without the expense of maintaining a 
fully loaded, fully redundant ASR 5000 in a permanent state of standby. 
The PDIF supports online software upgrades with a single software version difference between two chassis. For 
example, upgrading from Release 8.1 to 8.2 is supported. Support for a chassis running greater differences in software 
versions would be qualified by Cisco on an as-needed basis. 
Important:
  Refer to the Maintenance chapter in this guide for information on how to perform the upgrade. 
The online upgrade process calls for a spare ASR 5000 to temporarily perform the services currently being provided by 
a live networked chassis and upgrade the software with minimal service interruption. This model is called Active-
Standby, as one chassis is designated as active and the other as standby. The standby chassis does not handle any new, 
incoming sessions because the DNS allocating new sessions does not know about the backup chassis. The backup is 
only required to handle sessions that were already on the primary chassis when it was administratively disconnected 
from the DNS server. Except for the data loss during the brief chassis switch-over, the session information (accounting 
and timers) are synchronized so that they are accurate when the backup becomes the active PDIF. 
Important:
  Online upgrade requires miscellaneous internal processing that may result in intensive CPU 
utilization. Up to 50% CPU utilization overhead should be expected during the upgrade. 
 
The Active-Standby Upgrade Model 
 
The Active-Standby model is shown below: